=========================== R E L E A S E N O T E S =========================== Broadcom Advanced Server Program (BASP) Driver for Windows XP (x86 and IA64), 2000, NT 4.0 and .NET beta (x86 and IA64) Version 3.0.15 Copyright (c) 2000-2002 Broadcom Corporation All rights reserved. May 23, 2002 CHANGES in v3.0.15 ------------------ - Added support of additional Broadcom NetXtreme based NICs and LOMs. CHANGES in v3.0.14 ------------------ - Added support of additional Broadcom NetXtreme based NICs and LOMs. CHANGES in v3.0.13 ------------------ - Fixed Prod00004015: System bugcheck after created 802.3ad team on a .NET IA64 system. CHANGES in v3.0.11 ------------------ - Fixed Prod00003790: fails 2c_PMHibernate NDIS test on XP32. CHANGES in v3.0.10 ------------------ - Fixed Prod00003745: fails 1c_reset NDIS test on W2K. CHANGES in v3.0.9 ----------------- - Fixed Prod00003665: fails 1c_reset NDIS test on XP32. CHANGES in v3.0.8 ----------------- - Fixed Prod00003609: fails 1c_kernelcalls test. - Fixed Prod00003666: fails to add multiple cards with identical names into the teams. CHANGES in v3.0.7 ----------------- - Fixed 2c_Simultaneous test script failure with BASP on XP32. CHANGES in v3.0.6 ----------------- - Fixed Prod00003600: Windows XP Professional BASP teaming does not WOL from ping CHANGES in v3.0.5 ----------------- - Fixed Prod00003107: Load balancing does not occur on multiple hot-standby adapters. - Fixed signability errors with INF files. CHANGES in v3.0.4 ----------------- - Fixed few minor IEEE 802.3ad interoperability issues. CHANGES in v3.0.3 ----------------- - Enhance event notification mechanism. - Fixed system crash with the IEEE 802.3ad team in NT 4.0. - Add Trouble-shooting section to document known issues. CHANGES in v3.0.2 ----------------- - Fixed second port blocking problem in the IEEE 802.3ad team. CHANGES in v3.0.1 ----------------- - Support IEEE 802.3ad link aggregation. CHANGES in v2.0.6 ----------------- - Minor textual changes in INF and DLL. CHANGES in v2.0.5 ----------------- - Fixed Prod00002106: System Crashes after Deleting Vlan with ID 0 and another Vlan. CHANGES in v2.0.4 ----------------- - Fixed Prod00001753: loss of static IP address problem when disconnect all the NICs in a team and then only connect the hot-standy NIC. - Fixed Prod00001694: the BASP installer does not indicate the if the BASP already installed. - Fixed Prod00001779: BASP installation process is asking for BASPXPI.EXE while running BASPI64I.EXE install program. CHANGES in v2.0.3 ----------------- - Minor fix in installation and configuration GUI. CHANGES in v2.0.2 ----------------- - Enhanced installation and configuration GUI. CHANGES in v2.0.1 ----------------- - Updated teaming configuration. - Improved error reporting when configuring more than 8 physical NICs in a team. CHANGES in v1.3.3 ----------------- - Fixed the driver update issue on NT 4.0. This issue was introduced by v1.3.2. CHANGES in v1.3.2 ----------------- - Improved the reset operation on the virtual miniport instances. CHANGES in v1.3.1 ----------------- - Added support of IA-64 version of Windows.NET Beta 2. CHANGES in v1.3.0 ----------------- - Improved Windows 2000 userability by reducing traffic interruption in reconfiguring the team. In case of HotSwap, users can simply remove the adapter without reconfiguring the team if the replacement adapter carry the plug and play ID and the replaced adapter will not plug into network again. In case of HotRemove, users can remove the adapter without changing team configuration if the removed adapter will not plug into network. Team configuration will automatically adjusted when team configuration software launched. CHANGES in v1.2.11 ------------------ - Fix: error in re-installing BASP for Windows 2000. In version 1.2.10, the first time installation works fine without any error. However, if the BASP is removed and then re-installed again, a message box will be poped up during installation and display following message: "Unknown Installation Error". Despite this message, BASP is still installed properly. To configure the teaming, the user is required to manually bring up the BASP configuration dialog. - Fix: removal of a NIC from a Generic Trunking team may result duplicated MAC addresses on a network. CHANGES in v1.2.10 ------------------ - Fix: unable to resume from hibernation on Windows 2000. CHANGES in v1.2.9 ----------------- - Fix the failure in re-enabling the virtual miniport instances on Windows 2000. CHANGES in v1.2.8 ----------------- - Fix: loss of network connectivity when performance monitor is monitoring VLAN network segment. CHANGES in v1.2.7 ----------------- - Improved SNMP trap support in the BASP driver. CHANGES in v1.2.6 ----------------- - Fix: Individual adapters maintain team MAC address after a FEC/GEC team is removed on Windows 2000. [0798] - Fix: Description on virtual adapter is shown incorrectly when running ipconfig /all on Windows NT 4.0. [0803] CHANGES in v1.2.5 ----------------- - Fix: BASP W2K configuration GUI allows up to 39 characters for a team name. [0795]. - Fix: BASP W2K configuration GUI is updated to allow all 64 VLANs properly configured and functional. [0780] CHANGES in v1.2.4 ----------------- - Fix: Intermitten recovery failure with fiber network adapters. [0093] CHANGES in v1.2.3 ----------------- - Fix W2K INF files to pass signability test. CHANGES in v1.2.2 ----------------- - BASP is enhanced to work better with multiple protocols. [0608], [0671] - Fix: system bugcheck when NetXray is executed. [0305] CHANGES in v1.2.1 ----------------- - Added support of SNMP trap in the BASP driver. - Fix: Installing both BASP and PPTP on NT 4.0 causes "Exception error". [0573] - Rename the driver and DLLs files with BASP prefix. [0559], [0557], [0550] - Minor changes in configuration GUI dialog. [0529], [0250] - New upgrade procedure for Windows 2000: [0050], [0040] BASP in W2k can not be updated as the 'Description' section. Users need to save the original configuration through the driver configuration page, uninstall BASP, reboot machine, install new BASP and restore the origial team configuration. There are two new buttons added to the configuration GUI. One is to save configuration and the other is to restore configuration previously saved. There are some limitations/rules for the upgrade procedure. 1. The protocol related information like IP address will not be saved and restored. users need to reconfigured again after teams restored. 2. The physical NICs on the system should not be changed during the upgrade procedure. If any NIC can not matched during restoration, the NIC will be dropped. 3. If any team configuration can not be parsed, the restoration procedeure will be aborted. The format of the saved configuration is as following: a. The team configuration key word 'Load Balance Team Configuration' has to be at the start of a line followed by 0x0D and 0x0A (line break). b. Next line should contain the key word 'Team Name : ' followed by the team name which followed by 0x0D and 0x0A. Note that the spaces in the key word are expected and this rule will apply to other key words too. Team name can not be empty. c. Next line should contain key word 'Team type : ' followed by team type. The supported team types are 'Smart Load Balance and Fail Over' and 'Generic Trunking (FEC/ GEC)'. Team type will be followed 0x0D and 0x0A. Team type can not be empty. d. Next line should contain key word 'Load Balance Member : ' or 'Stand By Member : ' followed by the NIC name. NIC name has to match a NIC on the system, otherwise it will be dropped. NIC name will be followed by 0x0D and 0x0A. e. Next line should either repeat the same format as description for team member/stand by NIC or 0x0D 0x0A to end the team member/stand by section. f. After team member/stand by section, next line should contain key word 'VLAN Member : ' followed by VLAN name or 0x0D 0x0A if the team does not have VLAN configured. If VLAN name exists, it should be ended by 0x0D 0x0A. g. Next line should contain key word 'VLAN ID : ' followed by VLAN tag (a number) or 0 if no VLAN configured. the line should be ended by 0x0D 0x0A. h. Next line should be the beginning of another VLAN confuration (with key word 'VLAN Member : ') or 0x0D 0x0A to end the VLAN configuration. i. Next line should be the beginning of another team configuration (with key word 'Team Name : ') or 0x0D 0x0A to end 'Load Balance Team Configuration' section. 4. All team configuration rules will apply to the parsed configuration. Any disqualified team configuration will be dropped. Users should always check the parsed configuration and modify if they want. 5. If no valid team configuration parsed, the original configuration should remain. CHANGES in v1.1.10 ------------------ - Fix: Unnecessary dialog box in team configuration. [0443] CHANGES in v1.1.9 ----------------- - New feature: Support protocol independent failover on Broadcom 5700 only team. For team which contains not only Broadcom 5700 adapters, there is still IP protocol failover as existed in previous release. No user configuration is required to activate this feature. - Fix: System crash when primary adapter is either disabled (on W2K) or removed (on NT 4.0 and W2K), AND after system reboots. [0046], [0098], [0106], [0120]. - Fix: Netmon stops capturing after disconnect the cable of the primary NIC. [0053]. - Fix: Not all 64 VLAN are working. [0245], [0269] CHANGES in v1.1.8 ----------------- - Fix: Update the BASF driver with older version caused error. [0096] - Fix: FEC/GEC Property dialog does not show MAC address after reboot. [0270] - Fix: The standby adapter of FEC/GEC team receives inbound traffic from switch. [0297] - Fix: VLANs are not functional with BCM5700 A1 boards. [0298] - Fix: Failover does not occur to hot-standby adpater after all load-balancing adapters are removed and system reboots. [0046], [0098], [0106], [0120] - Fix: Recovery does not occur to load-balancing adapters when there is hot- standby adapter in the team. [0055], [0093] - Fix: System crash when NetXRay is run. [0305] CHANGES in v1.1.7 ----------------- - Fix: Unable to configure a FEC/GEC team with Tigon 2 and third party adapters. - Fix: Grammatical error of the message displayed during FEC/GEC team configuration. CHANGES in v1.1.6 ----------------- - Various fixes to address UI, installation and software update issues. - Support up to 64 VLAN per team. CHANGES in v1.1.5 ----------------- - Fix: NT 4.0 bugchecks with multiple Tigon 2 adapters on a Multi-Processor system. CHANGES in v1.1.4 ----------------- - Fix: BASF NT 4.0 driver bugchecks with multiple network adapters in a team during system boot. CHANGES in v1.1.3 ----------------- - Added 15 VLAN support per team. - Added Generic Trunking/FEC/GEC load balancing support. - Fixed a problem in distributing traffic to the network adapters that recover from link loss. CHANGES DETAILS in v1.1.3 ------------------------- - VLAN Starting from this release (v1.1.3), VLAN support is added to BASF driver. In each team, up to 15 VLAN can be added. Each added VLAN will result in a virtual adapter appearing in the protocol stack. In the case of TCP/IP, each VLAN corresponds to a network interface. VLAN support is orthogonal to the existing load balancing and failover features, which means customers who want VLAN will enjoy the same Smart Load Balancing and newly added Generic Trunking support. VLAN support is only available with following network adapters (1) BCM5700 gigabit adapter (2) Alteon Tigon 2 gigabit adapter VLAN addition will fail if an unlisted network adapter is added to the team. - Generic Trunking/FEC/GEC In addition to the original switch-independent Smart Load Balancing algorithm, a switch dependent load balancing algorithm, Generic Trunking or Cisco FEC/GEC compatible, is added. To properly configuring Generic Trunking, an unique MAC address is required. During Generic Trunking configuration, BASF will query one of the network adapter in the team and present its MAC address to the user for modification. The resultant MAC address will be written to the NDIS "NetworkAddress" registry key of all network adapters which belong to the team. A reboot is required to make this change effective. However, since the NDIS "NetworkAddress" registry key support is not a mandatory feature of NDIS driver, it is possible that some network adapters do not support. Most of the popular network adapters, as we verified, support this feature. When there is any question, please consult the corresponding network adapter vendors for details. Generic Trunking also REQUIRES network switches to support Cisco FEC/GEC and to be PROPERLY configured. Consult the switch documentation for setting up trunking. TROUBLE SHOOTING SECTION ------------------------ (1) 802.3ad team member links disconnect and reconnect continuously when connects to the HP2524 switch. This is a 3rd party issue. It is seen only when configuring an 802.3ad team with greater than 2 members on the server and connecting an HP2524 switch, with lacp enabled as passive or active. The HP switch will show an lacp channel being brought up successfully with only 2 members. All other member's links will disconnect and reconnect. This does not occur with a Cisco Catalyst 6500.